Lincoln sp 125 plus problems - I have an SP135+, a slightly newer version of the 125+. It usually feeds OK but every once in a while it will go in fits and starts. The problem is usually too much pressure on the nut (maybe a wing nut) that holds the wire spool in place. But check the whole feed path - only takes a minute or two.

 
Lincoln SP 125 Plus. $500 ... Save. Save. Share. Details. Condition. Used - Good. It's a little dusty but it works great no problems at all and that's a good price .... Lady hamilton ostatnia milosc lorda nelsona 1995

926. It could possibly be that you liner is kinked from being coiled too tightly. Another thing to try first is when you are welding is keep the cable to the gun straight as possible. Higher guage wire doesn't travel around curves well as lighter gauge. A really cheap fix is to replace the contact tip.I was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.CHANGING DRIVE ROLL The SP-100 Wire Feed Drive Roll (1 ) has two grooves; one for 0.023” – 0.025” (0,6 mm) solid steel electrode and the other for 0.030” (0,8 mm) solid and 0.035” (O,9 mm) flux-cored steel electrode. Page 28 9. Screw the gas diffuser onto the end of the gun tube and securely tighten. 10.You need to blow out your cable liner, while your doing this make sure your contact tip is clean and unobstructed. Also make sure that your drive roll tension is not to much, enough to move the wire but not enough to push it when you have the wire held at the gun.Cleanliness in a wirefeed insures problem free usability. Good luck.LB.Wire question for the Lincoln SP-125+. By Date 01-25-2008 06:23. I bought an unused Lincoln SP-125 Plus MIG machine. It can run .023 / .025 / .030 Hardwires and .035 Flux-core (Innershield). The machine shows you can run all of those diameter wires with the existing drive rollers, but you can also purchase the optional knurled rollers for the ...Start with the drive roll pressure very loose. Increase the pressure only until it is very difficult to stop the wire from feeding out of the contact tip. Use a pliers or block of wood to try and stop the wire from feeding. Go perhaps one-half of a turn beyond this point.Jun 15, 2007 · I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250. 1 Post Thanks / Like Replacing Diodes on Lincoln sp125 plus. 20 plus yrs of use I cant send it to scrap Well Ive already picked up an Amico 140 welder off home depots website and its not too bad for the price. Its not as adjustable as my 125 plus. I can lay a damn nice bead with the old lincoln.Lincoln 175 or Miller 175 would be my choice, they only cost about $200 more than a 135. If 220V is a problem for you (and you don't have a dryer outlet near by) check some of the dual voltage machines like the Miller DVI. 1965 Scout 80 7.3PSD/ZF/203/205 D60F/14BFF. Member: 4 Jackstand Wheeler's Association.To start, try the most common wire type, ER70S-3 (Lincoln L50) which contains 0.9-1.4 percent manganese and 0.45-0.75 percent silicon. If porosity is still present in the finished weld, increase the amount of silicon and manganese found in the wire by switching to an ER70S-4 (Lincoln L54) or an ER70S-6 which has the highest levels of silicon (0 ...This item, Lincoln Electric SP-125 Plus, is part of the online auction: H & L Steel Erectors - Complete Sellout - Construction Equipment & Tools.Find many great new & used options and get the best deals for Lincoln Electric Sp-125 Plus Wire Feed MIG Suitcase Welder at the best online prices at eBay! Free shipping for many products!SOURCE: 2000 lincoln continental stuck Make sure you have brake lights.This is were the shifter solenoid gets it's signal from to get it out of gear. One thing you can try is turn the igntion switch towards the run postion stopping just short of activating the electronics.Then try and move shifter to neutral then you can start it and out it into gear so you can drive it to get it fixed.02-23-2004, 07:56 PM. Use your eyes ,nose and hands to locate the problem. First Turn the machine on. Can you hear the transformer hum? if you can the problem is in the secondary wiring . IF you can not hear the transformer hum the problem is in the primary power side.It doesn't matter whether you measure amps or volts because it' the watts (power) that make heat. A 120V MIG welder turned all the way up will put out about 90A at 18V, around 1600W. A stick weld with a 3/32" 7018 or 1/8" 6010/6011 at 85A will be around 26V or 2200W, significantly more power.Summary of Contents for Lincoln Electric IM536-D. Page 1 • World's Leader in Welding and Cutting Products • • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com RETURN TO MAIN MENU SP- 125 PLUS 10260, 10481,10685 ...I bought a new lincoln SP-125 plus, probably 8-10 years ago, for packing upstairs on the back deck to do final installations on railings. The little guy does okay in the shop, but I quickly noticed that electricians just can't see the merit in running a #12 wire with a 20 amp breaker upstairs to the back deck of any house.Hey Guys! I have a Lincoln SP-125 Plus (mig) that's worked without fail for years. This morning I plugged it in and squeezed the trigger and the unit violently hummed and rattled. After trying a few times the breaker in my panel popped. After resetting breaker I noticed the wire was still feeding.Home › SP-125 PLUS HTP Replacement Gun & Parts SP-125 PLUS HTP Replacement Gun & Parts HTP America® MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.(55) 55 product ratings - Lincoln SP-180T Mig Welder 220V Recondition 180 Amps Welds Flux Core or Gas $700.00 Trending at $762.50 eBay determines this price through a machine learned model of the product's sale prices within the last 90 days.Hello. Info please. I have a used lincoln sp-125 hd. I bought this for a upcomming thin-wall exhaust project. Thought id get in some practice for a while before i attempt the actual thing. By the way the 125 is pretty dam powerful. I am using .025 lincoln solid wire with NO gas as I dont have a tank yet.Package includes gun and cable, work clamp and cable, input power cord, guide tubes and drive rolls, gas solenoid valve, gas regulator, and spool of wire. 115V operation-no special wiring required. Solid state output control for long life and repetitive welding applications. Designed for .023"-.030" solid MIG wire and .035" flux-cored wire.926. It could possibly be that you liner is kinked from being coiled too tightly. Another thing to try first is when you are welding is keep the cable to the gun straight as possible. Higher guage wire doesn't travel around curves well as lighter gauge. A really cheap fix is to replace the contact tip.(55) 55 product ratings - Lincoln SP-180T Mig Welder 220V Recondition 180 Amps Welds Flux Core or Gas $700.00 Trending at $762.50 eBay determines this price through a machine learned model of the product's sale prices within the last 90 days.Jan 10, 2013 · 50 Post Thanks / Like lincoln sp 125 plus Hey yall... I just got an older lincoln sp 125 plus and the panel/door doesnt match. I believe it was changed. Its a wel pak 100 door but its not a weld pak 100. It doesnt have the tap amp dial like it suggests, it has the continuous adjustment knob on top. 02-23-2004, 07:56 PM. Use your eyes ,nose and hands to locate the problem. First Turn the machine on. Can you hear the transformer hum? if you can the problem is in the secondary wiring . IF you can not hear the transformer hum the problem is in the primary power side.This item, Lincoln Electric SP-125 Plus, is part of the online auction: H & L Steel Erectors - Complete Sellout - Construction Equipment & Tools.No Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...Lincoln Electric IM536 SP-125 Plus User Manual • Troubleshooting, Troubleshooting guide, Caution • Lincoln Electric EquipmentI had two mm130 one was a 130 xp. I would say a fair comparison would be to a Lincoln sp 125 plus. The cost was about even ($500.00 new) The MM 130 was really not much of a welder but the xp version could more then hold it's own with the 125 Lincoln. I prefer the MM 130 xp over the new MM 135, My XP came with the Hobart OXO gun, that was really ...I will address a feed problem I have with my Lincoln 256 Power Mig welder. The problem is erratic feeding of the wire while welding. This problem started fro...Conical Nozzle, 3-Pack, f/Tweco® Mini MIG & Tweco® #1 Style MIG Welding GunsDec 30, 2019 · The Lincoln SP 125 is 120 volt and uses a 20 amp breaker. That is a problem with 120 volt welders. 1) see can change the welder to 240 volt some Lincoln welder can be changed. 2) I fix by buying a 240 volt welder. 3) cheat use a 30 amp breaker some will use the dryer breaker in the garage. No Hassle Tool-less Design for wire spool mounting, wire drive service and polarity changes. 30-125 amps output. 115V. Flux-core ready out of the box (not upgradeable to MIG). Innovative contact tip, drive roll and nozzle storage keeps all your consumables close at hand. 20% duty cycle @ 90A. Welds from 18 gauge up to 1/4" steel using Flux core ...Lincoln Electric is one of the world's largest manufacturers of industrial welding supplies, and WeldingMart is the largest online Lincoln welder parts dealer. We also carry a selection of parts from Miller Electric. Whether you're repairing an older welder or upgrading a new one, our high-quality welder parts and service will help make it happen.To start, try the most common wire type, ER70S-3 (Lincoln L50) which contains 0.9-1.4 percent manganese and 0.45-0.75 percent silicon. If porosity is still present in the finished weld, increase the amount of silicon and manganese found in the wire by switching to an ER70S-4 (Lincoln L54) or an ER70S-6 which has the highest levels of silicon (0 ...Lincoln Electric Global Sites - Select Your Country or Region. Welcome to Lincoln Electric! We are the world leader in the design, development and manufacture of arc welding products, robotic arc-welding systems, plasma and oxyfuel cutting equipment and have a leading global position in the brazing and soldering alloys market.Looking for parts for Lincoln mig welder sp130t, – – Looking for parts for Lincoln mig welder sp130t, need part m15787-2, g1839,and drive roll, Any idea where to – MIG Welders question Lincoln Welder – Farm Supply Ranch – lincoln electric k639 1 suction head manual 12 inch lincoln sp 125 plus arc welder in excellent condition 9.99 ...33 Post Thanks / Like Lincoln SP-125 - Not feeding wire I have a Lincoln SP-125 (just picked up used) that is now not feeding wire. The unit turns on, fan starts, and when you pull the trigger you hear a click as if it wants to feed, but nothing. I checked the poles on the drive motor and it does not appear that there is any voltage... Ideas?Jun 15, 2007 · I am going to look at a Lincoln SP 125 Plus later this afternoon and wondered if there is anything I should pay particular attention to. Does this machine have any quirks? The machine comes with a bottle, not sure of the size or if it is full or not, and the asking price $250. Step 4: Re-seat the Trigger. place the trigger back into its housing. the little tabs sticking out at the front and back should fit easily into depressions in the gun body. There will be some compression of the spring so you may need to keep a finger on the trigger to get it to stay put. After you are sure that everything is aligned properly ...Find operator's manuals for your Lincoln Electric welders, wirefeeders, guns, and accessories. ... SP125 Plus - 10740. Operator Manual English. 10689. IM536.Need some help with my "new to me" welder. I am having problems with my welder, its a Lincoln SP250 welder (ditigal version). I am getting a lot of sticking and "blast off" with weld porosity. The weld are are narrow and ropy, the gun are "kicking" back at me. I changed the liner, tip and nozzle. I am using .35 solid steel with 75/25 Argon/CO2.I had two mm130 one was a 130 xp. I would say a fair comparison would be to a Lincoln sp 125 plus. The cost was about even ($500.00 new) The MM 130 was really not much of a welder but the xp version could more then hold it's own with the 125 Lincoln. I prefer the MM 130 xp over the new MM 135, My XP came with the Hobart OXO gun, that was really ...Drive Roll Replacement For Lincoln KP666-035C .035 Inch Knurled Flux Cored Wire Used on Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus Welder $28.99 $ 28 . 99 FREE delivery Wed, Sep 13There seems to be a problem serving the request at this time. breadcrumb. ... $125.00. $10.25 shipping. or Best Offer. ... New Listing Lincoln Welder Parts L10952-2BO ...Welding Equipment; Cutting Equipment; Gear & Tools; Accessories; Welding Wire, Flux & Rods; Guns & Torches; Automated Welding & Cutting Systems; Training Equipment for EducatorsLoosen set screw in power pin and pull out liner. Have gun straight. Blow out gun and install new liner. before cutting liner install brass diffuser. with gun out straight cut liner flush with end of diffuser. use a side cutter and not a cutting wheel. split coils, bend to 45 degrees and cut.I was looking at purchasing my first welder for use at home and was interested in the SP135 plus. The question I have is this: I see it comes all set up to weld with solid wire and gas. The website says it can do flux core welding, which I have experience in the past.New listings: Lincoln SP-100 wire welder - $225 (Clarence), Lincoln Electric Welder SP-125 Plus 120 Volt - $275 (ELKHART) POST AD FREE. Free Local Classifieds .Hey Guys! I have a Lincoln SP-125 Plus (mig) that's worked without fail for years. This morning I plugged it in and squeezed the trigger and the unit violently hummed and rattled. After trying a few times the breaker in my panel popped. After resetting breaker I noticed the wire was still feeding.Hello. Info please. I have a used lincoln sp-125 hd. I bought this for a upcomming thin-wall exhaust project. Thought id get in some practice for a while before i attempt the actual thing. By the way the 125 is pretty dam powerful. I am using .025 lincoln solid wire with NO gas as I dont have a tank yet.Sep 17, 2011 · #1 hello, to all. i joined here hoping someone could help me out. i have a lincoln sp-125 plus. the thing worked awsome. It was stored in my dads basement on the floor and the city storm drain backed up and put 3in of water into the machine. I tried to use it the other day and this is what happened. Lincoln Electric926. It could possibly be that you liner is kinked from being coiled too tightly. Another thing to try first is when you are welding is keep the cable to the gun straight as possible. Higher guage wire doesn't travel around curves well as lighter gauge. A really cheap fix is to replace the contact tip.Package includes gun and cable, work clamp and cable, input power cord, guide tubes and drive rolls, gas solenoid valve, gas regulator, and spool of wire. 115V operation-no special wiring required. Solid state output control for long life and repetitive welding applications. Designed for .023"-.030" solid MIG wire and .035" flux-cored wire.Tweet. #17. 08-26-2014, 05:41 AM. Originally posted by cruizer View Post. Generally with that unit its going to be a mechnical circuit board mounted relay. Heck I have a box full of solder in tab 12 volt or was it 5 volt coil relays purchased for a project and never got done. Brand new.Basic wire welding for projects and repairs around the shop farm or home that where the Weld-Pak 125 HD comes in handy. Plug in the Weld-Pak 125 HD anywhere common 120-Volt input power is available. Set the simple 2 knobs tapped control for your material application and get it done. Right out of the box, the Weld-Pak is set up for gas-less flux ...02-04-2010 #1 Guard Solderer Join Date Feb 2010 Posts 4 Post Thanks / Like SP125 plus problems? Hello, I've had this for years w/gas bottle, and loved it so far! A few days ago trying to weld-up a snow blade for a 4-wheeler, It did fine for about 10 minutes, about 3-4 ins. of bead at a time, then quit putting anything out.33 Post Thanks / Like Lincoln SP-125 - Not feeding wire I have a Lincoln SP-125 (just picked up used) that is now not feeding wire. The unit turns on, fan starts, and when you pull the trigger you hear a click as if it wants to feed, but nothing. I checked the poles on the drive motor and it does not appear that there is any voltage... Ideas?PAGE 1. RETURN TO MAIN MENU IM536-D SP-125 PLUS March, 2001 For use with machine Code Numbers 10260, 10481,10685,10689,10690,10740 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind.SP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistantDrive Roll 023-.035 For Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus. Opens in a new window or tab. Brand New. $19.49. Save up to 5% when you buy more ...Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.Home › SP-125 PLUS HTP Flex Neck Gun & Parts SP-125 PLUS HTP Flex Neck Gun & Parts HTP America® 15 Series flex neck MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.Lincoln Electric IM536 SP-125 Plus User Manual • Troubleshooting, Troubleshooting guide, Caution • Lincoln Electric EquipmentI bought a new lincoln SP-125 plus, probably 8-10 years ago, for packing upstairs on the back deck to do final installations on railings. The little guy does okay in the shop, but I quickly noticed that electricians just can't see the merit in running a #12 wire with a 20 amp breaker upstairs to the back deck of any house.If your machine is a SP-125T, check the voltage selector switch. A bad switch will kill both weld power and wire feed. A bad switch will also prevent power from getting to the rectifier. A bad rectifier will take out both weld and wire feed in either an SP-125T or an SP-125-PLUS. Cheers,Lincoln SP 135 Plus VS HH 135. 07-16-2003, 06:34 AM. This last weekend I had to do some more repair work again on an auger in one of our large potato bins- differnent bin then last time. This time so that I didn t have to bring in my HH 135 the boss rented me a machine. The only machine that was available was a Lincoln Sp 135 Plus.Tweet. #17. 08-26-2014, 05:41 AM. Originally posted by cruizer View Post. Generally with that unit its going to be a mechnical circuit board mounted relay. Heck I have a box full of solder in tab 12 volt or was it 5 volt coil relays purchased for a project and never got done. Brand new.This item, Lincoln Electric SP-125 Plus, is part of the online auction: H & L Steel Erectors - Complete Sellout - Construction Equipment & Tools.Rick get the sp-135 plus.Its a great little welder.With .023 stainless wire,and the right gas the little lincoln will spray arc.Thats pretty impressive performance.I just traded my little miller 130xp in on a sp-175 plus its a great little welder also.Spend the extra at the welding store,because you will get support if needed.That could make up the difference even if you bought a 135 tapped ...Ideal replacement for Lincoln Magnum 100L (K530-6). Usually, Lincoln Magnum 100L (K530-6) MIG gun can be found on SP-140T/180T, MIG-Pak 140/180, ProMIG 140/180, Weld-Pak 125HD/140HD/180HD, Power MIG 140C/180C and EasyCore 140/180, etc. welders. Use standard front consumables 21 series nozzle, 11 series tip and xx-40-15 liner.Quality of work comes before profit! Old Fashion "Customer is always right policy". 1 year warranty. Fair Estimates on all Lincoln units. Low Prices. To have your Lincoln unit repaired/tested call 1- (336)-969-0110. Make. Part Number. Model Number.Summary of Contents for Lincoln Electric IM536-D. Page 1 • World's Leader in Welding and Cutting Products • • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com RETURN TO MAIN MENU SP- 125 PLUS 10260, 10481,10685 ...Ad id: 3012175658160591. Views: 3523. Price: $379.00. LINCOLN 125 MIG WELDER. AS NEW CONDITION, LESS THAN ONE HOUR USE. 120V. WELDS UP TO 1/4 INCH STEEL WITH FLUX CORE WIRE. Report. Last Updated on: August 30, 2023 with LINCOLN 125 MIG WELDER SP 125 PLUS - $379 (NASSAU)Drive Roll 023-.035 For Lincoln SP-100, SP-125 Plus, SP-135 Plus and SP-175 Plus. Opens in a new window or tab. Brand New. $19.49. Save up to 5% when you buy more ...If you have any problems with the registration process or your account login, please contact support. Results 1 to 2 of 2 ... Lincoln SP 125 plusYour #1 Source for Lincoln welder parts on the internet. Choose a link Below. I Know My Part Number; I would like to find the Part Number; I would like to Call or E-mail. Allow 7-10 Day on all Ground orders under $99. All orders over $99 will Ship 3-4 days. If you need Special Shipping please give us a call at 866-922-8147.lincoln sp-125 plus; idealarc 250/250; any one know where i can get a manuale for this; Couple of sa200 questions; Opportunity to pick up a Lincoln 175 for $175, good deal? Help with PrecisionTig 275 Advanced Panel Install; Will spool gun work with Wire-Matic 255 Mig; Lincoln Invertec V350-Pro w/ pulse. K1728-7; Lincoln DC 250 MK Arc WelderProduct Names and Code Numbers can be found on the name plate of welders and wirefeeders. In order to ensure you have the correct Operator's Manual for your machine you must use a Code Number Search.Find operator's manuals for your Lincoln Electric welders, wirefeeders, guns, and accessories. ... SP125 Plus - 10740. Operator Manual English. 10689. IM536.Lincoln SP 135 Plus VS HH 135. 07-16-2003, 06:34 AM. This last weekend I had to do some more repair work again on an auger in one of our large potato bins- differnent bin then last time. This time so that I didn t have to bring in my HH 135 the boss rented me a machine. The only machine that was available was a Lincoln Sp 135 Plus.

It started humming and blowing breakers so i did the research and tested the diodes. They failed. People are saying to replace all of them at same time because if one fails then it usually takes out the other. i found the 9sm9661-39 and 9sm9661-39r diodes online but they are running like 50 each. i remember while searching for a cheaper option .... Ss.suspected

lincoln sp 125 plus problems

Rick get the sp-135 plus.Its a great little welder.With .023 stainless wire,and the right gas the little lincoln will spray arc.Thats pretty impressive performance.I just traded my little miller 130xp in on a sp-175 plus its a great little welder also.Spend the extra at the welding store,because you will get support if needed.That could make up the difference even if you bought a 135 tapped ...Lincoln SP-130; Lincoln spool gun ? SA200 - A Sheer Joy to Work on; lincoln tombstone tig ? Sp-130t; SA-200 wiring diagram; Pro-Mig 135 liner replacement problems; Buying my LN-25 Tomorrow :D :D; A/C D/C 225/125 mfg date. Lincoln-Pak 100 Mig conversion Quesion of regulator type; Lincoln is official welder of Jay Leno's garage; Lincoln ...One sure sign is if the wire burns back in the contact tip. That could mean about 10 different things. Is this what is happening. John. SMAW,GMAW,FCAW,GTAW,SAW,PAC/PAW/OFC. and Shielding Gases.1 - locate mains contactor in machine - operate torch switch - does contactor operate ( you will hear it clearly ) 2 - if it operates check mains is live when contactor is energized ( high mileage units can have the contacts burned away or contaminated ) 3 - now check live is going up to the voltage selector switch.Lincoln SP-130; Lincoln spool gun ? SA200 - A Sheer Joy to Work on; lincoln tombstone tig ? Sp-130t; SA-200 wiring diagram; Pro-Mig 135 liner replacement problems; Buying my LN-25 Tomorrow :D :D; A/C D/C 225/125 mfg date. Lincoln-Pak 100 Mig conversion Quesion of regulator type; Lincoln is official welder of Jay Leno's garage; Lincoln ...To start, try the most common wire type, ER70S-3 (Lincoln L50) which contains 0.9-1.4 percent manganese and 0.45-0.75 percent silicon. If porosity is still present in the finished weld, increase the amount of silicon and manganese found in the wire by switching to an ER70S-4 (Lincoln L54) or an ER70S-6 which has the highest levels of silicon (0 ...Home › SP-125 PLUS HTP Flex Neck Gun & Parts SP-125 PLUS HTP Flex Neck Gun & Parts HTP America® 15 Series flex neck MIG welding gun and parts/consumables for LINCOLN® SP-125 PLUS MIG welders.SP-125 PLUS ORDER FORM DISTRIBUTED BY: THE LINCOLN ELECTRIC COMPANY Local Sales and Service through Global Subsidiaries and Distributors Cleveland, Ohio 44117-1199 U.S.A TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com Wire Feeder / Welders E7.20 3/00 PRODUCT DESCRIPTION ORDER NUMBER QUANTITY PRICE SP-125 Plus K660-3 ...It works fine with my Lincoln Innershield flux-core 0.035" diameter wire on my Lincoln SP-125 Plus welder with the standard Magnum 100L gun. Plenty of extra length--easy to cut-to-length with side cutters. The 10-24 set screw that holds the original liner in place was too long for the new liner so I substituted a shorter one.Bad Karma wrote: I have a Lincoln SP-125, looks to be very similar to 3200HD, and have not had a problem with anything that I have tried to weld with it. As far as the price, sounds good, depending on condition of the unit. Does it come with a tank for gas? Any accessories? Are you sure that it works? Just some things to think about.lincoln sp-125 plus; idealarc 250/250; any one know where i can get a manuale for this; Couple of sa200 questions; Opportunity to pick up a Lincoln 175 for $175, good deal? Help with PrecisionTig 275 Advanced Panel Install; Will spool gun work with Wire-Matic 255 Mig; Lincoln Invertec V350-Pro w/ pulse. K1728-7; Lincoln DC 250 MK Arc WelderVEVOR MIG Welding Gun Torch 100A 11.5FT Replacement for Lincoln 100L K530-5. $30.99. $48.99. Free shipping. Hover to zoom.Lincoln SP 135 Plus VS HH 135. 07-16-2003, 06:34 AM. This last weekend I had to do some more repair work again on an auger in one of our large potato bins- differnent bin then last time. This time so that I didn t have to bring in my HH 135 the boss rented me a machine. The only machine that was available was a Lincoln Sp 135 Plus.If you have any problems with the registration process or your account login, please contact support. Results 1 to 1 of 1 Thread: MIG Welder for Sale - Lincoln SP-125 PlusSP-125 PLUS ii SAFETY ii ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant.